Scand J Clin Lab Invest ; 83(1): 60-63, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36448677

RESUMO

This study aimed to examine the agreement of the serum amyloid A (SAA) values determined using the ELISA test and the nephelometric automated method. This study included 80 serum samples obtained from patients with COVID-19. Samples were determined using ELISA and the nephelometric method. Wilcoxon signed ranks test showed a statistically significant difference in the calculated median values (Z = -2.432, p = 0.015). The correlation between methods was statistically significant (r = 0.603, p < 0.0001). Bland Altman analysis showed a bias of 56.6 mg/L and a relative bias of 7.4% between the methods. The results of this study indicate that further studies are needed that will examine the compliance between the ELISA and the nephelometric method for determining SAA, and the results must be carefully interpreted based on the method used.


Assuntos
COVID-19 , Proteína Amiloide A Sérica , Humanos , Proteína Amiloide A Sérica/análise , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática , Nefelometria e Turbidimetria
2.
J Med Biochem ; 41(2): 211-220, 2022 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-35510209

RESUMO

Background: Thyrotropin receptor autoantibodies (TSH-RAb) are indispensable biomarkers in the laboratory assessment of thyroid-associated orbitopathy (TAO). Clinical sensitivity of three different assays for TSH-R-Ab determination was evaluated in patients with TAO. Methods: 87 consecutive TAO patients were enrolled and their serum samples analyzed in parallel with three assays. An ECLIA competitive binding and a chemiluminescent bridge immunoassay were used to measure total and binding TSH-R-Ab concentration, while their functional activity was determined using a stimulatory TSH-R-Ab (TSAb) cellbased bioassay. Results: Compared to the two binding assays (ECLIA p<0.001, bridge p=0.003), the TSAb bioassay was more sensitive pertaining to the positive detection of TSH-R-Ab in TAO patients. No difference (p=0.057) was noted between the ECLIA and bridge assays regarding sensitivity rate. All patients with active and/or moderate-to-severe TAO tested positive in the TSAb bioassay (100% and 100%, respectively), while the positivity rates for bridge and ECLIA binding assays were 89.7% and 82.1% for active TAO, and 90.2% and 86.3% for severe TAO, respectively. Negative predictive values of the bioassay, bridge, and ECLIA assays were 100%, 75%, and 71%, respectively for active TAO, and 100%, 86%, and 71%, respectively for moderate-to-severe TAO. The superiority of the bioassay was most prominent in euthyroid (ET) TAO. Positivity rates of the TSAb bioassay, bridge and ECLIA binding assays were 89.6%, 75%, and 64.6%, respectively for inactive TAO; 86.1%, 69.4%, and 52.8%, respectively for mild TAO; 87.5%, 62.5%, and 12.5%, respectively for euthyroid TAO. The bridge assay correlated better with the ECLIA binding assay (r=0.893, p<0.001), compared to the bioassay (r=0.669, p<0.001). Conclusions: In patients with TAO of various activity and severity, the TSAb bioassay demonstrates a superior clinical performance compared to both ECLIA and bridge binding assays.

3.
J Med Biochem ; 39(2): 178-183, 2020 Jan 23.
Artigo em Inglês | MEDLINE | ID: mdl-33033450

RESUMO

BACKGROUND: Problem of the variability between the different methods using for bone alkaline phosphatase (bALP) determination greately influences the clinical significance of bALP as direct marker of bone metabolism. The aim of this study was to compare immunoassay with electrophoresis technique for bALP determination. METHODS: We measured bALP in 71 patients on hemo - dialysis with agar gel electrophoresis (ISO-PAL, SEBIA) and immunoassay (OSTASE, Beckman Coulter). RESULTS: The analyzed methods showed significant correlation (Spearman's rho: 0.776, P < 0.01), but we found statistically significant (P < 0.01) positive bias (27%) for the results measured by immunoassay. In support of this, using electrophoresis technique we have detected presence of the intestinal isoenzymes of alkaline phosphatase in 55% of patients with median value of 30% of the total alkaline phoshatase and presence of liver-2 alkaline phosphatase isoform in 42% of patients with median value of 16.6%. The Kendall's W of 0.787 (P<0.0001) revealed significant concordance between two analysed methods. Cusum test showed no significant deviation from linearity (P=0.850). CONCLUSIONS: Despite good agreement between immuno - assay methods and electrophoresis technique for bALP determination, interchangeability between these two methods is questionable. Although immunoassays are increasingly used, as fully automated methods, in a large number of laboratories and become routine methods for bALP determination, it should be beared in mind, besides various interferences, also the heterogeneity of the bALP itself, especially in patients on hemodialysis.

4.
RSC Adv ; 10(5): 2846-2855, 2020 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-35496114

RESUMO

In this study, the in vivo hypoglycemic effect of a donut-shaped polyanion salt (NH4)14[Na@P5W30O110]·31H2O {NaP5W30} and its Ag-containing derivative K14[Ag@P5W30O110]·22H2O·6KCl {AgP5W30}, as well as their hepatotoxicity and nephrotoxicity, was evaluated. In the screening hypoglycemic study, Wistar albino rats with streptozotocin induced diabetes were treated intraperitoneally with three single doses (5, 10, and 20 mg per kg per b.w.) of both investigated polyoxotungstates. The blood glucose levels, measured before and after 2, 4 and 6 h polyoxotungstate application, showed that both studied compounds induced the most pronounced and time dependent glucose lowering effects at the doses of 20 mg kg-1. Thus, daily doses of 20 mg kg-1 were administered to Wistar albino rats orally for 14 days in further toxicity examinations. The serum glucose concentration and biochemical parameters of kidney and liver function, as well as a histopathological analysis of kidney and liver tissues were evaluated 14 days after the polyoxotungstate administration. Both investigated compounds did not induce statistically significant alterations of the serum glucose and uric acid concentrations, as well as some of the liver function markers (serum alanine and aspartate aminotransferases, and alkaline phosphatase activities). However, the significant decrease in serum total protein and albumin concentrations and the increase in biochemical parameters of renal function - serum urea (up to 63.1%) and creatinine concentrations (up to 23.3%) were observed for both polyoxotungstates. In addition, the detected biochemical changes were in accordance with kidney and liver histhopathological analysis. Accordingly, the hepatotoxic and nephrotoxic effects of these potential antidiabetic polyoxotungstates could be considered as mild.